| Air bank | A certified, registered pressure vessel, in a protected enclosure | requirement R-13 in the design definition; the roof interface |
| Stored energy in the bank | 4.66 kJ per litre at 30 bar | calculated as adiabatic expansion energy; the formula reproduces the reference bank's published figure |
| Relief valve | 33 bar set point, 110 % of working pressure | set point on the pneumatic diagram |
| Relief capacity | Sized for full compressor flow and proven by a switch in the arm chain | requirement R-13 in the design definition |
| Relief and vent discharge | Routed clear of people and of the building's air intakes | design definition, stored air on the roof |
| Pressure reading | A transmitter on the bank, 0 to 40 bar, and a local gauge | the pneumatic equipment list |
| Isolation and venting | A manual isolation valve locked open in operation, and a manual vent and drain that takes the bank to zero, confirmed on the local gauge | requirement R-17 in the design definition; the pneumatic energy-isolation note |
| Compressor | Electric, 17 kW shaft power, on three phase | the reference design's sizing |
| Site supply | Three phase; 480 V in the reference design. The motor and the supply are specified per site. | the supply the reference electrical design is drawn to; Canadian institutional sites commonly run at 600 or 208 V |
| Control bus | 24 VDC, physically segregated from the three-phase side | the launcher's bus architecture |
| Voltage-drop limit on the control bus | 3 % | the limit the inherited load analysis sets itself |
| Uninterruptible supply | Carries an orderly return to SAFE and keeps the sensor head running on loss of supply; it does not carry the drives | design definition, power |
| Loss of supply | Safe regardless, because the breech is normally closed | design definition, power |
| Electrical installation | To CSA C22.1, with the three-phase and 24 VDC buses physically segregated | requirement R-19 in the design definition. Named as a design basis, with no conformity asserted. |
| Control link | CAN 2.0B, point-to-point from the controller to the operator station, at 250 kbit/s; 40 m on copper at that rate, and over fibre beyond it together with the interlock loop | the controller specification's limit; the fibre rule added in the design definition |
| Video and track network | Ethernet over fibre, segregated, view-only status to site security | design definition, the network in three parts |
| Cybersecurity | Designed to IEC 62443. Named as a design basis, with no conformity asserted. | design definition, the network in three parts |
| External data ports | None on the mount; the fire-control connector is physically capped when not in use | design definition, the network in three parts |
| Earthing and surge | The protective bond, surge protection on every copper entry, and fibre for every data run off the mount | design definition, earthing |